Arizona Sun and Wind got the check today,So things are starting to move my way on the pv system.
and that's the way it is.
cheers.
.bb
These pv panels are rated @ 23.6 volts for grid tie operation or stand alone MPPT charge controllers, You series 2 of these together for 5 strings of 47.2 volts @ 7.84 amps per pair.This complies with current N.E.C. code. Code correct "Under 48 volts" for pv systems. 1850 watts total system @ 24 volts.
Xantrex XW MPPT-SCC 60 amp Charge Controller
This charge controller will convert the 47.2 volt PV array @ 39.2 amps and convert down to charge a 24 volt battery bank.This is a 3 stage controller. Bulk, Absorption and Float with manual equalization.
The charge rate will be 27.2 volts up to 29.0 volts @ 53 amps during the 6 hour prime sun,period 10:00am till 4:00pm. Although I get much more sun than 6 hours,It would charge my banks with a 50% state of discharge or (DOD) in the 6 hour period. The charge controller will compensate automatically during the day.Worth the money....
We purchased 8 of these Trojan L16RE-B 6 volt battery's.These will be arranged into 24 volt battery banks.There will be 2 banks rated at 375 AH @ 20 amp rate.The 2 banks will deliver 750 AH @ 24 volts. Expected life span 5 to 8 years with proper care. weight 118lbs each (Bet ya I get 10 out of um)
I have left room for expansion if necessary. I think this will provide enough electricity for a fairly convenient life style.We will see....I will have a backup inverter just in case.